git diff abe8fe352711601fbcd24bf4505f7e0b81a93c5d..d3982bcd814bac93e3cbce1c7eb749b17e413fbd -- $(find . -type f -name '*en-us*')
12 KiB
title | license | origin_url |
---|---|---|
Logging Configuration | Apache-2.0 | d3982bcd81/docs/content/administration/logging-config.en-us.md |
The logging configuration of Forgejo mainly consists of 3 types of components:
- The
[log]
section for general configuration [log.<mode-name>]
sections for the configuration of different log writers to output logs, aka: "writer mode", the mode name is also used as "writer name".- The
[log]
section can also contain sub-logger configurations following the key schemalogger.<logger-name>.<CONFIG-KEY>
There is a fully functional log output by default, so it is not necessary to define one.
The [log]
section
Configuration of logging facilities in Forgejo happen in the [log]
section and its subsections.
In the top level [log]
section the following configurations can be placed:
ROOT_PATH
: (Default: %(GITEA_WORK_DIR)/log): Base path for log filesMODE
: (Default: console) List of log outputs to use for the Default logger.LEVEL
: (Default: Info) Least severe log events to persist, case-insensitive. Possible values are:Trace
,Debug
,Info
,Warn
,Error
,Fatal
.STACKTRACE_LEVEL
: (Default: None) For this and more severe events the stacktrace will be printed upon getting logged.
And it can contain the following sub-loggers:
logger.router.MODE
: (Default: ,): List of log outputs to use for the Router logger.logger.access.MODE
: (Default: <empty>) List of log outputs to use for the Access logger. By default, the access logger is disabled.logger.xorm.MODE
: (Default: ,) List of log outputs to use for the XORM logger.
Setting a comma (,
) to sub-logger's mode means making it use the default global MODE
.
Quick samples
Default (empty) Configuration
The empty configuration is equivalent to default:
[log]
ROOT_PATH = %(GITEA_WORK_DIR)/log
MODE = console
LEVEL = Info
STACKTRACE_LEVEL = None
logger.router.MODE = ,
logger.xorm.MODE = ,
logger.access.MODE =
; this is the config options of "console" mode (used by MODE=console above)
[log.console]
MODE = console
FLAGS = stdflags
PREFIX =
COLORIZE = true
This is equivalent to sending all logs to the console, with default Golang log being sent to the console log too.
This is only a sample, and it is the default, do not need to write it into your configuration file.
Disable Router logs and record some access logs to file
The Router logger is disabled, the access logs (>=Warn) goes into access.log
:
[log]
logger.router.MODE =
logger.access.MODE = access-file
[log.access-file]
MODE = file
LEVEL = Warn
FILE_NAME = access.log
Set different log levels for different modes
Default logs (>=Warn) goes into forgejo.log
, while Error logs goes into file-error.log
:
[log]
LEVEL = Warn
MODE = file, file-error
; by default, the "file" mode will record logs to %(log.ROOT_PATH)/forgejo.log, so we don't need to set it
; [log.file]
; by default, the MODE (actually it's the output writer of this logger) is taken from the section name, so we don't need to set it either
; MODE = file
[log.file-error]
MODE = file
LEVEL = Error
FILE_NAME = file-error.log
Log outputs (mode and writer)
Forgejo provides the following log output writers:
console
- Log tostdout
(orstderr
if it is set in the config)file
- Log to a fileconn
- Log to a socket (network or unix)
Common configuration
Certain configuration is common to all modes of log output:
MODE
is the mode of the log output writer. It will default to the mode name in the ini section. Thus[log.console]
will default toMODE = console
.LEVEL
is the lowest level that this output will log.STACKTRACE_LEVEL
is the lowest level that this output will print a stacktrace.COLORIZE
will default totrue
forconsole
as described, otherwise it will default tofalse
.
EXPRESSION
EXPRESSION
represents a regular expression that log events must match to be logged by the output writer.
Either the log message, (with colors removed), must match or the longfilename:linenumber:functionname
must match.
NB: the whole message or string doesn't need to completely match.
Please note this expression will be run in the writer's goroutine but not the logging event goroutine.
FLAGS
FLAGS
represents the preceding logging context information that is
printed before each message. It is a comma-separated string set. The order of values does not matter.
It defaults to stdflags
(= date,time,medfile,shortfuncname,levelinitial
)
Possible values are:
none
or,
- No flags.date
- the date in the local time zone:2009/01/23
.time
- the time in the local time zone:01:23:23
.microseconds
- microsecond resolution:01:23:23.123123
. Assumes time.longfile
- full file name and line number:/a/b/c/d.go:23
.shortfile
- final file name element and line number:d.go:23
.funcname
- function name of the caller:runtime.Caller()
.shortfuncname
- last part of the function name. Overridesfuncname
.utc
- if date or time is set, use UTC rather than the local time zone.levelinitial
- initial character of the provided level in brackets eg.[I]
for info.level
- level in brackets[INFO]
.gopid
- the Goroutine-PID of the context.medfile
- last 20 characters of the filename - equivalent toshortfile,longfile
.stdflags
- equivalent todate,time,medfile,shortfuncname,levelinitial
.
Console mode
In this mode the logger will forward log messages to the stdout and stderr streams attached to the Forgejo process.
For loggers in console mode, COLORIZE
will default to true
if not
on windows, or the Windows terminal can be set into ANSI mode or is a
cygwin or Msys pipe.
Settings:
STDERR
: false: Whether the logger should print tostderr
instead ofstdout
.
File mode
In this mode the logger will save log messages to a file.
Settings:
FILE_NAME
: The file to write the log events to, relative toROOT_PATH
, Default to%(ROOT_PATH)/forgejo.log
. Exception: access log will default to%(ROOT_PATH)/access.log
.MAX_SIZE_SHIFT
: 28: Maximum size shift of a single file. 28 represents 256Mb. For details see below.LOG_ROTATE
true: Whether to rotate the log files. TODO: if false, will it delete instead on daily rotate, or do nothing?.DAILY_ROTATE
: true: Whether to rotate logs daily.MAX_DAYS
: 7: Delete rotated log files after this number of days.COMPRESS
: true: Whether to compress old log files by default with gzip.COMPRESSION_LEVEL
: -1: Compression level. For details see below.
MAX_SIZE_SHIFT
defines the maximum size of a file by left shifting 1 the given number of times (1 << x
).
The useful values of COMPRESSION_LEVEL
are from 1 to (and including) 9, where higher numbers mean better compression.
Beware that better compression might come with higher resource usage.
Must be preceded with a -
sign.
Conn mode
In this mode the logger will send log messages over a network socket.
Settings:
ADDR
: :7020: Sets the address to connect to.PROTOCOL
: tcp: Set the protocol, either "tcp", "unix" or "udp".RECONNECT
: false: Try to reconnect when connection is lost.RECONNECT_ON_MSG
: false: Reconnect host for every single message.
The "Router" logger
The Router logger logs the following message types when Forgejo's route handlers work:
started
messages will be logged at TRACE levelpolling
/completed
routers will be logged at INFO. Exception: "/assets" static resource requests are also logged at TRACE.slow
routers will be logged at WARNfailed
routers will be logged at WARN
The "XORM" logger
To make XORM outputs SQL logs, the LOG_SQL
in [database]
section should also be set to true
.
The "Access" logger
The Access logger provides a NCSA Common Log compliant log format. It's highly configurable but caution should be taken when changing its template. The main benefit of this logger is that Forgejo can now log accesses in a standard log format so standard tools may be used.
You can enable this logger using logger.access.MODE = ...
.
If desired the format of the Access logger can be changed by changing
the value of the ACCESS_LOG_TEMPLATE
.
Please note, the access logger will log at INFO
level, setting the
LEVEL
of this logger to WARN
or above will result in no access logs.
The ACCESS_LOG_TEMPLATE
This value represents a go template. Its default value is
{{.Ctx.RemoteHost}} - {{.Identity}} {{.Start.Format "[02/Jan/2006:15:04:05 -0700]" }} "{{.Ctx.Req.Method}} {{.Ctx.Req.URL.RequestURI}} {{.Ctx.Req.Proto}}" {{.ResponseWriter.Status}} {{.ResponseWriter.Size}} "{{.Ctx.Req.Referer}}" "{{.Ctx.Req.UserAgent}}"`
The template is passed following options:
Ctx
is thecontext.Context
Identity
is theSignedUserName
or"-"
if the user is not logged inStart
is the start time of the requestResponseWriter
is thehttp.ResponseWriter
Caution must be taken when changing this template as it runs outside of the standard panic recovery trap. The template should also be as simple as it runs for every request.
Releasing-and-Reopening, Pausing and Resuming logging
If you are running on Unix you may wish to release-and-reopen logs in order to use logrotate
or other tools.
It is possible force Forgejo to release and reopen it's logging files and connections by sending SIGUSR1
to the
running process, or running forgejo manager logging release-and-reopen
.
Alternatively, you may wish to pause and resume logging - this can be accomplished through the use of the
forgejo manager logging pause
and forgejo manager logging resume
commands. Please note that whilst logging
is paused log events below INFO level will not be stored and only a limited number of events will be stored.
Logging may block, albeit temporarily, slowing Forgejo considerably whilst paused - therefore it is
recommended that pausing only done for a very short period of time.
Adding and removing logging whilst Forgejo is running
It is possible to add and remove logging whilst Forgejo is running using the forgejo manager logging add
and remove
subcommands.
This functionality can only adjust running log systems and cannot be used to start the access or router loggers if they
were not already initialized. If you wish to start these systems you are advised to adjust the app.ini and (gracefully) restart
the Forgejo service.
The main intention of these commands is to easily add a temporary logger to investigate problems on running systems where a restart may cause the issue to disappear.
Using logrotate
instead of built-in log rotation
Forgejo includes built-in log rotation, which should be enough for most deployments. However, if you instead want to use the logrotate
utility:
- Disable built-in log rotation by setting
LOG_ROTATE
tofalse
in yourapp.ini
. - Install
logrotate
. - Configure
logrotate
to match your deployment requirements, seeman 8 logrotate
for configuration syntax details. In thepostrotate/endscript
block send Forgejo aUSR1
signal viakill -USR1
orkill -10
to theforgejo
process itself, or runforgejo manager logging release-and-reopen
(with the appropriate environment). Ensure that your configurations apply to all files emitted by Forgejo loggers as described in the above sections. - Always do
logrotate /etc/logrotate.conf --debug
to test your configurations. - If you are using docker and are running from outside the container you can use
docker exec -u $OS_USER $CONTAINER_NAME sh -c 'forgejo manager logging release-and-reopen'
ordocker exec $CONTAINER_NAME sh -c '/bin/s6-svc -1 /etc/s6/gitea/'
or sendUSR1
directly to the Forgejo process itself.
The next logrotate
jobs will include your configurations, so no restart is needed.
You can also immediately reload logrotate
with logrotate /etc/logrotate.conf --force
.